N550
 Specifications
Electrical
Mechanical
Parameters
Components
Features

|
|
Electrical

|
Accelerating
Voltage |
-90kV
nominal (-110 kV maximum
continuous or pulsed |
|
|
Target
Current |
up to
100µ A |
|
|
Target
Power |
up to 10
watts |
|
|
Ion
Source Voltage |
2-2.5 kV
continuous or pulsed |
|
|
Ion
Source Current |
750µ A
typical |
|
|
Replenisher
Voltage |
1 volt
typical (3 volts maximum) |
|
|
Replenisher
Current |
1 amp
typical (2amps maximum) |
|
Mechanical 
|
Diameter |
30mm (1.18 inches) |
|
|
Length |
~155mm (6.1 inches) |
|
|
Weight |
200g. (~7 ounces) |
|
Parameters
|
Neutron
energy |
14 MeV for D-T tube
(2.5 MeV for D-D tube) |
|
|
Neutron
output |
>1.18 x 108
n/second |
|
|
Target |
< 5 Ci tritium
(~1.5-2.6 Ci typical) |
|
|
Repetition
rate |
1 Hz-10 kHz
(variable) |
|
|
Pulse width |
variable |
|
|
Duty cycle |
1%-50% (variable);
continuous also |
|
|
Tube ignition |
~5µ sec (rise and
fall time 1 to 5µ sec;
pressure dependent) |
|
|
Environment |
operating temperature
+5 to 125° C |
|
|
Insulating
medium |
transformer oil,
Fluorinert or SF6 |
|

Note: All ATC neutron generator
products are listed under the heading of equipment subject to the Nuclear
Non-Proliferation rules and regulations and United States Department of Commerce
regulations pertaining to end use(r) and final destination of product. ATC requires all
customers to sign and submit a statement on form acknowledging these requirements at the
time of order.
|