N550B![]() Specifications |
Internal
DC Voltage maximum DC current 60mA Output Pulse Voltage maximum current 20A peak.
Gate source is external and requires a pulse of +5 volts into a 50 ohm load. The rise time must be <20 nseconds and the minimum pulse width 10µ sec maximum is DC. The gate input connector is a BNC on the rear panel Current Transformer Output A current monitor (torroidal coil) is provided-- The output is through a BNC located on the rear panel Voltage Monitor Output A voltage monitor is provided with standard calibration The output is available through a BNC located on the rear panel 110/220 VAC, 50/60 Hz switchable 40° C typical ambient temperature, 60° C max. 19 inches wide by 5.25 inches high by 13 inches deep.Weight is 15lbs.
|
||||||||||||||
![]()
Send mail to ATC Webmaster with
questions or comments about this web site.
Copyright © 1998/2008 Activation Technology Corporation
Activation Technology Corporation, 2816 Janitell Road, Colorado Springs, Colorado 80906; 719-576-6557, FAX: 719-576-6550